|
|
Residuals of simethicone in endoscope clamp tract after high level disinfection and its effect on endoscopy |
QI Lina, XIA Wenzhong, YANG Shuxian |
Department of Gastroenterology, Characteristic Medical Center of the People’s Armed Police Force, Tianjin 300162, China |
|
|
Abstract Objective To analyze the amount of residuals of simethicone in the endoscope clamp tract after high level disinfection and its effect on endoscopy. Methods Aseptic water and simethicone at low, middle and high concentrations (0.5%, 1% and 3%) were used to rinse the endoscope clamp tract respectively. After strict cleaning and high-level disinfection, the SteriCam borescope was used to examine the residual fluid in the endoscope.The bioluminescent value of adenosine triphosphate (ATP) was measured as well. Results The amount of droplets and values of ATP bioluminescence in the endoscope clamp were significantly larger or higher when simethicone at a medium concentration (number of droplets:13.47±5.64, ATP value: 22.58±8.12) and a high concentration (number of droplets: 17.30±6.61, ATP value: 24.00±10.60)was used than when simethicone at a low concentration (number of droplets: 5.81±2.77, ATP value: 15.56±6.37) or sterile water was used(number of droplets: 6.30±3.52, ATP value: 10.97±4.84), P<0.05. The use of low-concentration simethicone did not increase the amount of residual droplets or values of ATP bioluminescence in the endoscope clamp. Conclusions Lowconcentration simethicone liquid is preferable. When high-concentration simethicone is used, two cycles of washout should be considered or the duration of washout should be extended appropriately.
|
Received: 10 March 2020
|
|
|
|
|
[1] |
张 松, 钟文其, 彭春艳,等. 西甲硅油乳剂在结肠镜检查肠道准备中的应用价值[J]. 中华消化内镜杂志, 2017, 34(9):645-648.
|
[2] |
李晓亮,唐红卫,文 姝, 等.结肠镜检查两种饮食准备方法对肠道准备质量的比较[J].武警医学,2019,30(8):651-653.
|
[3] |
Kovaleva J. Endoscope drying and its pitfalls[J]. J Hosp Infect, 2017, 147(3):034508.
|
[4] |
Ofstead C L, Wetzler H P, Johnson E A, et al. Simethicone residue remains inside gastrointestinal endoscopes despite reprocessing[J]. Am J Infect Control, 2016, 44(11):1237-1240.
|
[5] |
Ofstead C L,Wetzler H P, Heymann O L, et al. Longitudinal assessment of reprocessing effectiveness for colonoscopes and gastroscopes: results of visual inspections, biochemical markers, and microbial cultures[J]. Am J Infect Control, 2017, 45(2):e26-e33.
|
[6] |
黄 婵, 娄廼彬, 彭秋生,等. 不同干燥方法对消化内镜再处理效果的影响研究[J]. 中华医院感染学杂志, 2017, 27(20):4787-4790.
|
[7] |
Stiphout S, Laros I, Wezel R, et al. Crystallization in the waterjet channel in colonoscopes due to simethicone[J]. Endoscopy, 2016, 48(1):e394-e395.
|
[8] |
孙 昕, 邹瑞珍, 王 颖, 等. 西甲硅油在结肠镜检查前肠道准备中的应用[J]. 世界华人消化杂志, 2009, 17(2):218-220.
|
[9] |
Zhang L, Li W, Ji M, et al. Efficacy and safety of using premedication with simethicone/pronase during upper gastrointestinal endoscopy examination with sedation: a single center, prospective, single blinded, randomized controlled trial[J]. Digest Endosc, 2018,30(1):57-64.
|
[10] |
严拯宇, 艾小霞, 唐 璐,等. 红外分光光度法测定二甲硅油含量[J]. 中南药学, 2015(2) :180-181.
|
[11] |
常淑莹, 姚卓娅, 耿军辉,等. 探讨ATP生物荧光检测法对硬式内镜清洗效果的评价[J]. 中国消毒学杂志, 2018, 35(5):79-81.
|
[12] |
Wu L, Cao Y, Liao C, et al. Systematic review and meta-analysis of randomized controlled trials of simethicone for gastrointestinal endoscopic visibility[J]. Scand J Gastroentero, 2011, 46(2):227-235.
|
[13] |
张 松,钟文其,彭春艳,等.西甲硅油乳剂在结肠镜检查肠道准备中的应用价值[J]. 中华消化内镜杂志, 2017, 34(9):645-648.
|
[14] |
张志宏,邱春华,李良平.比较西甲硅油不同使用方法在胶囊内镜肠道准备中的效果[J]. 中华消化内镜杂志, 2016, 33(7):473-475.
|
[15] |
康书红, 蔺红丽, 吴素现,等. 消化道内镜检查患者感染的危险因素研究[J]. 中华医院感染学杂志, 2015, 25(24):5637-5639.
|
[1] |
. [J]. Med. J. Chin. Peop. Armed Poli. Forc., 2017, 28(10): 1050-1052. |
|
|
|
|