|
|
Curative effect of minimally invasive treatment of Rüedi-AllgöwerⅡ, Ⅲ closed Pilon fracture with L-shaped anatomical locking plates assisted by C-arm X-ray machine |
XU Peizhang1, ZHAN Xingwang2, CHEN Yuhua2, CHEN ZHAOhui3 |
1. Department of Orehopedics,Second Mobile Corps Hospital of Chinese People's Armed Police Force, Wuxi 214035, China;
2. Health Team of the Eighth Detachment of the Second Mobile Corps of the Chinese People's Armed Police Force, Mengzi 661199, China;
3. Institute of Medical Prevention and Control of Public Health Emergencies, Characteristic Medical Center of the Chinese People's Armed Police Force,Beijing 102613, China |
|
|
Abstract Objective To investigate the clinical effect of C-arm X-ray machine assisted minimally invasive treatment of 24 cases of Rüedi-AllgöwerⅡ, Ⅲ closed Pilon fractures withL-shaped anatomical locking plates.Methods C-arm X-ray machine was used to fluoroscope the fractures.Patients whose incision of tissuewas limited and fracture reduction was satisfactory were selected. L-shaped anatomical locking plateswere fixed well in these patients between January 2013 and December 2018.Results All the cases were followed up for 6 to 24 months, with anaverage of(15±3.25) months. The fracture healing of the patients was good. There were no such complications as wound infection, vascular injury or ankle stiffness. Only one patient developed traumatic arthritis, which returned to normalafter a year of rehabilitation. According to Mazur ankle function score and fracture reduction and healing degree evaluation, 16 patients were rated as excellent, 5 as good, and 3 as fair. The rate of excellent and good effect was 87.5%.Conclusions The curative effect of minimally invasive treatment of Rüedi-Allgöwer Ⅱ, Ⅲclosed Pilon fracture with L-shaped anatomical locking plates assisted by C-arm X-ray machine is satisfactory.
|
Received: 03 August 2020
|
|
|
|
|
[1] |
Deivaraju C, Vlasak R. Sadasivan K. Staged treatment of Pilon fractures [J]. J Orthop, 2015, 28: 1-6.
|
[2] |
唐佩福,王 岩.骨折手术学[M]. 北京:人民军医出版社,2013:578.
|
[3] |
Rüedi T, Allgöwer M. Fractures of the lower end of the tibia into the ankle Joint [J]. Injury, 1969, 1: 92-99.
|
[4] |
Mazur J M, Schwartz E, Simon S R. Ankle arthrodeses long-term follow-up with gait analysis [J]. J Bone Joint Surg (Am), 1979, 61: 964-975.
|
[5] |
Rüedi T. Intraarticular fractures of distal tibia:results after 9 years: author's transl [J]. Arch Orthop Unfallchirug,1973, 76(4):248-254.
|
[6] |
Rüedi T, Matter P, Allgöwer M. Intra-articular fractures of the distal tibial end [J]. Helv Chir Acta, 1968, 35(5): 556-582.
|
[7] |
Ovadia D N, Beals R K. Fractures of the tibial plafond [J]. J Bone Joint Surg Am, 1986, 68(4): 543-551.
|
[8] |
王海波,商 杰,王业华,等.两种方法治疗粉碎性Pilon骨折疗效分析[J]. 临床骨科杂志,2017, 20(2):206-210.
|
[9] |
黄永红,任学通,洪 斌, 等.有限切开L型锁定钢板内固定治疗Pilon骨折的临床应用[J]. 生物骨科材料与临床研究,2017, 14(5):74-75.
|
[10] |
陈小明,罗雪平,王 毅,等.前外侧入路L型锁定钢板治疗粉碎性Pilon骨折的临床效果观察[J]. 河南医学研究,2018, 27(22):4118-4119.
|
[11] |
Tornetta P Ⅲ,Group J. Axial computed tomography of Pilon fractures[J]. Clin Orthop Relat Res, 1996,323: 273-276.
|
[12] |
威塞尔(Wiesel,S.W.)主编. 张长青. WIESEL 骨科手术技巧. 创伤骨科[M]. 上海:上海科学技术出版社,2015: 486.
|
[13] |
Howard J L, Agel J, Barei D, et al. Challenging the dogma of the 7 cm rule: a prospective study evaluating incision placement and wound healing for tibial plafond fractures[C]. Phoenix: Orthopaedic Trauma Association annual meeting, Phoenix,AZ, 2006.
|
|
|
|