|
|
Comparion of high frequency ultrasound imaging and magnetic resonance imaging in measurement of normal anterior cruciate ligament |
XI Xiaoping1, YAN Wei1,DING Xue1,XU Wen1,ZHANG Yiliang1,and LIU Ruihong2 |
1.Department of Specific Care, Beijing Municipal Corps Hospital of Chinese People’s Armed Police Force, Beijing 100027, China; 2. Department of Ultrasound, Chenxinghai Hospital Affiliated to Guangdong Medical College, Zhongshan 528415, China |
|
|
Abstract Objective To test if the thickness of normal anterior cruciate ligament (ACL) can be measured by high frequency ultrasound(US). Methods The thickness of ACL near tibial insertion site was measured by US and magnetic resonance imaging(MRI) in 30 normal right knees of young male soldiers. The thickness of ACL near tibial insertion site which was measured by two different radiologists by US were compared and analysed. The thickness of ACL near tibial insertion site which was measured by US and MRI were compared and analysed. Results The intraclass correlation coefficient for these 2 radiologists was 0.934(95% CI:0.867 to 0.968) and Bland Altman plot showed that the mean difference was -0.04 ( 95% CI:-0.55 to 0.47 ), indicating a very strong agreement between these 2 radiologists in measuring the thickness of ACL by US. The intraclass correlation coefficient for US and MRI was 0.914 (95% CI:0.822 to 0.959) and Bland Altman plot showed the mean difference was 0.04 (95% CI:-0.62 to 0.70), indicating a very strong agreement between these 2 methods in measuring the thickness of ACL. Conclusions High frequency ultrasound can be used as a conventional method for measuring the thickness of ACL.
|
Received: 10 October 2015
|
|
|
|
|
[1] |
Van Dyck P, De Smet E, Veryser J, et al. Partial tear of the anterior cruciate ligament of the knee: injury patterns on MRI imaging[J]. Knee Surg Sports Traumatol Arthrosc, 2012,20(2):256-261.
|
[2] |
陈一武,王晓刚,施晓琳,等.高频超声在胸背部肌骨中的应用进展[J].医学综述,2014,20(10):1799-1803.
|
[3] |
雷志辉,王少特,金 鹏,等. 军事训练致膝关节滑膜炎的高频超声诊断[J].武警医学,2014,25(6):554-556.
|
[4] |
Grzelak P, Podgórski M T, Stefańczyk L,et al.Ultrasonographic test for complete anterior cruciate ligament injury [J].Indian J Orthop. 2015,49(2):143-149.
|
[5] |
陈君洁,梁峭嵘,刘照宏,等. 高频超声膝关节前交叉韧带损伤分级诊断与关节镜对比研究[J].中国中西医结合影像学杂志,2012,10(4):314-315.
|
[6] |
Sutton K M, Bullock J M. Anterior cruciate ligament rupture: differences between males and females[J]. J Am Acad Orthop Surg,2013,21(1):41-50.
|
[7] |
Ng A W, Lee R K, Ho E P, et al. Anterior cruciate ligament bundle measurement by MRII[J]. Skeletal Radiol,2013,42(11):1549-1554.
|
[8] |
王晓宇,杨 柳,陈 伟,等. 膝关节前交叉韧带解剖测量和M RI测量对照分析[J].重庆医学,2006,35(13):1171-1173.
|
[9] |
Nam T S, Kim M K, Ahn J H, et al. Efficacy of magnetic resonance imaging evaluation for meniscal tear in acute anterior cruciate ligament injuries[J].Arthroscopy,2014,30(4):475-482.
|
[10] |
何国超, 汪青春,向孝兵,等.前交叉韧带胫骨附着处临床解剖学研究[J].中国临床解剖学杂志,2011,29(2):155-158.
|
[11] |
Tate C M, Williams G N, Barrance P J, et al. Lower extremity muscle morphology in young athletes: an MRII-based analysis[J]. Med Sci Sports Exerc, 2006, 38(1):122-128.
|
|
|
|