Application of contrast-enhanced ultrasound in diagnosis and treatment of iatrogenic pseudoaneurysm |
YANG Meiling, LI Lili, CHEN Mei, WANG Libo, REN Xiuyun |
Department of Ultrasound, Hainan Hospital of PLA General Hospital,Sanya 572013, China |
|
|
Abstract Objective To explore the value of contrast-enhanced ultrasound (CEUS) in diagnosis, treatment and efficacy evaluation of iatrogenic pseudoaneurysms (IPSA). Methods A retrospective analysis was conducted on the data of 39 patients with IPSA diagnosed and treated at the Hainan Hospital of PLA General Hospital from January 2013 to March 2024. Before treatment, conventional ultrasound was used to measure the size of the aneurysm, the diameter of the fistula, and the blood flow velocity of the fistula. CEUS was performed when necessary. The treatment options were as follows: compression therapy as the first choice, followed by ultrasound-guided thrombin occlusion for those who failed in compression therapy, and surgical intervention or covered stent implantation for those who failed in the above treatments or had contraindications. Statistical analysis was conducted on the parameters such as aneurysm size, fistula diameter, and blood flow velocity in the successful treatment groups. Results There were 34 cases (34/39, 87.18% ) of simple pseudoaneurysm and 5 cases (5/39, 12.82%) of complex pseudoaneurysm (combined with arteriovenous fistula or multiple aneurysms, etc.). Statistically significant differences were found in aneurysm size between the compression group and the thrombin occlusion group (P=0.048) as well as between the compression group and the surgical group (P=0.013). Similarly, statistically significant differences were observed in fistula size between the compression group and the thrombin occlusion group (P=0.006) and between the compression group and the surgical group (P=0.043). However, no statistically significant difference was found in blood flow velocity among the compression, thrombin occlusion, or surgical group. Conclusions CEUS is an effective diagnostic method for complex IPSA, and thrombin occlusion is an effective remedy for IPSA patients after failure of compression therapy.
|
Received: 08 July 2024
|
|
|
|
|
[1] |
Chun E J.Ultrasonographic evaluation of complications related to transfemoral arterial procedures [J]. Ultrasonography, 2018,37(2):164-173.
|
[2] |
Toursarkissian B,Allen B T,Petrinec D, et al. Spontaneous closure of selected iatrogenic pseudoaneurysms and arteriovenous fistulae[J]. J Vasc Surg,1997,25(5):803-809.
|
[3] |
钱朝庆,刘 淼,李发旺,等.超声引导下ProGlide血管缝合器腔内治疗股动脉假性动脉瘤1例[J].中国介入影像与治疗学, 2023, 20(3):190.
|
[4] |
郭方舟,聂 芳.超声诊断股浅动脉假性动脉瘤血栓形成并股浅动静脉瘘1例[J].临床超声医学杂志,2023,25(2):100-104.
|
[5] |
陈 重,李 茜,陶 杰,等.超声造影在经皮注射凝血酶原治疗肢体假性动脉瘤中的应用[J].解放军医学杂志,2014,39(1):40-43
|
[6] |
甄艳华,卢学峰,邱敬涛,等.超声引导下凝血酶注射术治疗股动脉假性动脉瘤的临床应用价值[J].河南外科学杂志, 2018, 24(4):2-4
|
[7] |
韩 威, 刘新林, 曾 晖. 主动脉破裂出血伴假性动脉瘤形成1例[J]. 武警医学, 2006, (4): 290-291.
|
[8] |
李海华,徐 强,王 哲. 超声引导下凝血酶治疗医源性股动脉假性动脉瘤的Meta分析[J]. 临床超声医学杂志, 2019, 21 (3):197-200.
|
[9] |
任小龙,付晓燕,吕建红,等.超声造影在引导假性动脉瘤微创治疗中的初步应用[J].中国超声医学杂志,2015,31(2):161-163.
|
[10] |
Ehieli W L,Bozdogan E, Janas G,et al.Imaging-guided percutaneous thrombin injection for the treatment of iatrogenic femoral artery pseudoaneurysms [J].Abdom Radiol(NY),2019,44(3):1120-1126.
|
[11] |
钟 锐,刘晓琳,林 勇,等.改良法超声引导下分次注射小剂量凝血酶治疗股动脉假性动脉瘤的应用价值[J].中国血管外科杂志:电子版,2018,10(1):46-49.
|
[12] |
苟 博,王天瑞,辛风月,等. 超声引导下压迫联合瘤腔注射凝血酶治疗医源性假性动脉瘤的临床观察[J]. 成都医学院学报, 2021, 16(2):176-179.
|
[13] |
赵亚莉,房 达,王 群,等.超声引导下凝血酶注射治疗肝动脉化疗栓塞术后股动脉假性动脉瘤的临床观察[J].中国超声医学杂志, 2021,37(2):164-166.
|
[14] |
陈晓琴,刘 政,张 洁,等.超声引导下假性动脉瘤内注药封堵术的安全性和有效性研究[J].临床超声医学杂志, 2019, 21(11): 868- 870
|
[15] |
马 力,闫 盛.医源性股动脉假性动脉瘤的诊疗进展[J].中国药物与临床,2020,20(1):47-49.
|
[16] |
Saydam O, Serefli D, Engin A Y, et al. Ultrasound-guided thrombin injection for treatment of iatrogenic femoral artery pseudoaneurysms compared with open surgery: first experiences from a single institution[J]. Ann Surg Treat Res,2020,98(5): 270-276.
|
|
|
|