Effects of irradiation intensity on the bond strength of dual-cure resin adhesive
ZU Bin1 and MIAO Li2
1.Department of Prosthodontics,Beijing Chongwen Hospital of Stomatology,Beijing 100062, China; 2.Department of Stomatology, Beijing Military General Hospital of PLA, Beijing 100700, China
Abstract:Objective To evaluate the intensity of irradiation after penetrating dentin, and compare the effects of cure-light on the micro-tensile bond strength (mTBS) of dual-cure dental adhesive.Methods The superficial dentin of occlusal surface (40 molars) were exposed and applied with Clearfil DC Bond(A ) or Clearfil SE Bond (B), then bonded together through light-cure from mesial dejection. The bond specimens were cut into sticks(bonding area 1 mm×1 mm) along the direction of light-cure (L1-5) , and tested with Micro-Tensile Tester for mTBS. The statistical analysis was performed using SPSS11.0.Results After penetrating dentin of 1 mm and 2 mm thickness, the light irradiation decreased to (114±28) mWcm-2 and (28±11)mWcm-2, respectively. Some stick samples were broken during preparation, and the fracture occurred at the bonding interface. The remaining samples were SE: L1 70%, L2 30%, L3-L5 0%; DC: L1 to L5 was 68%, 86%, 56%, 44%,38% . The mTBS were (13.22±8.64) MPa (L1), (7.49±3.88) MPa (L2) and 0 MPa (L3 and L4) for SE,(11.25±4.11) MPa (L1), (9.69±5.07) MPa (L2), (8.13±4.88) MPa (L3), (6.83±3.53) MPa (L4) and (5.56±2.95) MPa for DC. There was no significant difference between DC and SE regarding the mTBS of L1 and L2.Conclusions The mTBS of dual-cureresin adhesive decreased with the increase of cure-light penetrating depth of dentin.
祖 斌, 苗 莉. 光强度对双固化树脂黏接剂与牙本质黏接强度的影响[J]. 武警医学, 2016, 27(6): 574-576.
ZU Bin and MIAO Li. Effects of irradiation intensity on the bond strength of dual-cure resin adhesive. Med. J. Chin. Peop. Armed Poli. Forc., 2016, 27(6): 574-576.
Papazoglou E, Rahiotis C, Kakaboura A, et al. Polymerization efficiency of dual-polymerized resin cements light-irradiated through ceramics andlaboratory-processed resin composite[J]. Eur J Prosthodont Restor Dent,2008,16(1):15-19.
[3]
Feng L, Carvalho R, Suh B I. Insufficient cure under the condition of highirradiance and short irradiation time[J]. Dent Mater, 2009,25(3):283-289.
[4]
Breschi L, Mazzoni A, Ruggeri A, et al. Dental adhesion review: agingand stability of the bonded interface[J]. Dent Mater, 2008,24(1):90-101.
[5]
Jung H, Friedl K H, Hiller K A, et al. Curing efficiency of differentpolymerization methods through ceramic restorations[J]. Clin OralInvestig, 2001,5(3):156-161.
[6]
Aravamudhana K, Rakowskib D, Fanc P L. Variation of depth of cure and intensity withdistance using LED curing lights [J]. Dent mater, 2006,22(11):988-994.
[7]
Felix C A,Price R B.The effect of distance from light source on light intensity from curing lights[J].J Adhes Dent,2003,5(4):283-291.
[8]
Rode K M,Kawano Y,Turbino M L.Evaluation of curing light distance on resin composite microhardness and polymerization[J].Oper Dent,2007,32(6):571-578.
[9]
Price R B, Murphy D G, Dérand T. Light energy transmissionthrough cured resin composite and human dentin [J].Quintessence Int,2000, 31(9):659-667.
[10]
Ruyter I E, Oysaed H. Conversion in different depths ofultraviolet and visible light activated composite materials [J].Acta Odontol Scand, 1982, 40(3):179-192.
[11]
Ferracane J L, Mitchem J C, Condon J R, et al. Wear and marginal breakdown of composites with various degrees of cure [J].J Dent Res,1997,76(8):1508-1516.
[12]
Sideridou I D, Achilias D S. Elution study of unreactedBis-GMA, TEGDMA, UDMA, and Bis-EMA from light-cureddental resins and resin composites using HPLC [J]. J BiomedMater Res B Appl Biomater, 2005, 74(2):617-626.
[13]
Leprince J G,Palin W M,Hadis M A,et al.Progress in dime thacrylate-based dental composite technology and curing efficiency[J].Dent Mater,2013,29(2):139-156.
[14]
Jung H,Friedl K H, Hiller K A, et al.Polymerization efficiencyof different photocuring units through ceramic discs [J]. Oper Dent, 2006, 31(1):68-77.
[15]
Kilinc E, Antonson S A,Hardigan P C, et al.The effect of ceramic restoration shade and thickness on the polymerization of light- and dual-cure resin cements[J]. Oper Dent, 2011, 36(6): 661-669.
[16]
Pires-de-Souza Fde C, Drubi Filho B, Casemiro L A, et al. Polymerization shrinkage stress of composites photo-activated by different light sources[J]. Braz Dent J, 2009,20(4): 319-324.
[17]
Yoshida K,Atsuta M.Post-irradiation hardening of dual-cured and light-cured resin cements through machinable ceramics[J].Am J Dent,2006,19(5):303-307.
[18]
Lee J W,Cha H S,Lee J H.Curing efficiency of various resin-based materials polymerized through different ceramic thicknesses and curing time [J] .J Adv Prosthodont,2011,3(3):126-131.