A comparative study of effect of prepackaged diet and self made low-residue diet on quality of bowel preparation
LI Xiaoliang1,TANG Hongwei2,WEN Shu1,CHI Jinfeng1,HAN Guang1,and WEI Linghao1
1.Nursing Deparment,Beijing Municipal Corps Hospital of Chinese People’s Armed Police Force, Beijing 100027,China; 2.Department of Gastroenterology,Beijing Tsinghua Chang Geng Hospital,Beijing 100070,China
Abstract:Objective To compare the effect of two different dietary regimens on quality of bowel preparation among patients intended for colonoscopy.Methods In this study, 150 patients who underwent colonoscopy were selected as subjects, who were randomly divided into two groups: the pre-packaged group and the self-provided group, with 75 cases in each. Single-center, single-blind, prospective and controlled studies were conducted. The patients of the pre-packaged group(group of pre-packaged diet) took pre-packaged food for three meals a day before the examination, while the patients of the self-provided group(the low-residue diet group)took the low-residue diet provided by themselves one day before the examination. The intestine-rinsing fluid used by both groups was 3L sulfate-free polyethylene glycol electrolyte powder and patients took it orally at 4:00 a.m. on the day of examination.Results The detection rate of polypus was 37.3% for the pre-packaged group and 32.0% for the self-provided group. There was no significant difference between the two groups (P>0.05).In terms of the time for the first defecation, the pre-packaged group scored 46.25±28.23, which was significantly lower than that of the self-provided group(65.34±34.54)(P<0.05). In terms of insertion time, the pre-packaged group scored (5.35±1.63),which was lower than that of the self-provided group (8.24±2.26)(P<0.05).Conclusions The prepackaged diet can shorten the time interval before the first defecation, reduce the frequency of defecation,shorten the insertion time of, and improve the quality of colonoscopy.
李晓亮,唐红卫,文姝,池金凤,韩光,魏凌浩. 结肠镜检查两种饮食准备方法对肠道准备质量的比较[J]. 武警医学, 2019, 30(8): 651-653.
LI Xiaoliang,TANG Hongwei,WEN Shu,CHI Jinfeng,HAN Guang,and WEI Linghao. A comparative study of effect of prepackaged diet and self made low-residue diet on quality of bowel preparation. Med. J. Chin. Peop. Armed Poli. Forc., 2019, 30(8): 651-653.
Faiss S.The missed colorecstal cancer problem[J].Dig Dis,2011,29(1):30-63.
[2]
Froehlich F,Wietlisbach V,Gonvers J J,et al.Impact of colonic cleaning on quality and diagnostic yield of colonoscopy:the European panel of appro-priateness of gasreointestinal endoscopy european multicenter study[J].Gastrointest Endosc,2005,61(1):378-384.
[3]
Jung Y S,Seok H S,Park D I,et al.A clear liquid diet is not mandatory for Polyethylene Glycol-Based Bowel preparation for afternoon colonoscopy in healthy outpatients[J].Gut Liver,2013,7(6):681-687.
[4]
Eun H S,Tae O K,Min J P,et al.Optimal preparation to colonoscopy interval in split-dose PEG bowel preparation determins satisfactory bowel preparation quality: an observational prospectivestudy [J].Gastrointest Endoc, 2012, 75(3): 583- 592.
[5]
Bhanthumkomol P,Siramolpiwat S,Vilaichone R K,et al.Incidence and predictors of inadequate bowel preparation bofore elective colonoscopy in Thai patients[J].Acian Pac J Cancer Prev,2014,15(24):10763-10768.
[6]
Flemming J A,Green J,Melicharkova A,et al.Low-residul breakfast during the preparation for colonoscopy using a polyethylene glycol electrolyte solution:a randomised non-inferiority trial[J].BMJ Open,2015,10(2):112-117.
[7]
Harewood G C,Sharma V K,de Garmo P.Impact of colonoscopy preparation quality on detection of suspected colonic neoplasia[J].Gastrointest Endosc,2003,58:76-79.
[8]
Sherer E A,Imler T D,Imperiale T F.The effect of colonoscopy prparation[J].Gastrointest Endosc,2012,75(3):545-553.
[9]
Wu K L,Rayner C,Chuan S K,et al.Impact of low-residue on bowel preparation for colonoscopy[J].Dis Colon Rectum,2011,54(1):101-112.
[10]
Chou C K,Chang C Y,Chang C C,et al.Controlled dietary restriction with a prepackaged low-residue diet before colonoscopy offers better-quality bowel cleaning and allows the use of a smaller volume of purgatives:a randomized mul-ticenter trial[J].Dis Colon Rectum,2016,59(10):975-983.
[11]
Fan J, Fu H Y, Ma D,et al.Constipation,fiber intake and noncomplian-e contribute to inadequate col-onoscopy bowel preparation:a prospective cohort study[J].J Dig Dis,2016,17(7):458-463.
[12]
Park D I,Park S H,Lee S K,et al.Efficacy of prepackaged,low-residual test meals with 4L polyethylene glycol versus a clear liquid diet with 4L polyethylene glycol bowel preparation:a randomized trial[J]. J Gastroenterol Hepatol, 2009,24:988-991.
[13]
Cho Y Y,Kim H.Effect of a patient educational video program on bowel preparation prior to colonoscopy[J].J Korean Acad Nurs,2015,45(5):704-712.
[14]
Ergen W F,Pascricha T,Hubbard,et al.Providing hospitalized patients with an educational booklet increase the quality of colonoscopy bowel preparation[J].Clin Gastroenterol Hepatol,2016,14(6):858-864.
[15]
Lee Y J,Kim E S,Park K S.Education for ward nurses influences the quality of inpatient bowel preparation for colonoscopy[J].Medicine,2015,94(34):e1423.
[16]
Kang X,Zhao L,Leung F,et al.Dlivery of instruction via mobile social media app incerase quality of bowel preparation[J].Clin Gastroenterol Hepatal,2016,14(3):429-435.
[17]
Lee J Y,Kim E S,Choi J H,et al.Impact of reinforced education by telephone and short massage service on the quality of bowel preparation:a randomized controlled study[J].Endoscopy,2015,47(11):1018-1027.
[18]
Seo E H,Kim T O,Park M J,et al.Low-volume morning-only polyethlene glycol with specially designed test m-eals versus standard volume split-dose polyethlene glycol with sdandard diet for colonoscopy:a prospective,randozed trial[J].Digestion,2013,88(2):110-118.