Radiation hazards during X-ray physical examinations by high-end imaging |
DI Rujie1, SUN Zhenxue1, CHENG Zhongqu1, ZHANG Haixia2, LIU Hui1, LI Xinfu1, XI Ke1, TIAN Xinlei1 |
1.Clinical Department of Senior Officer Health Care, General Hospital of Chinese People’s Armed Police Force, Beijing 100073, China 2.Institute for Bacterial Disease Prevention and Control & Disinfection, Hebei Province Center for Disease Control and Prevention, Shijiazhuang 050021, China |
|
|
Abstract Objective To study X-ray radiation exposure among recipients of physical checkups via high-end imaging in order to reduce possible hazards.Methods The data on X-ray examinations among these subjects was analyzed, their annual dose and cumulative radiation dose were calculated, and they were grouped by the annual average dose. The correlations between the positive changes in spots of repeated irradiation and the dose of irradiation were analyzed.Results The annual average dose of X-ray irradiation among these subjects was 4.59 mSv, and reached the medium dose level (3-20 mSv). 116 of these subjects received repeated CT examination at the same spot. Among the 34 subjects with positive changes, 25(73.53%) were in the middle radiation dose group and 7 in the low radiation dose group. There was no statistically significant difference in positive or negative rates of detection between the two groups. There was also no statistically significant difference in gender or age between the low dose radiation group (43.33%) and middle dose radiation group (56.67%).Conclusions The cumulative radiation dose of X-ray is somewhat large in this population. Many people have been subjected to unnecessary CT examinations. How to protect this population from radiation hazards is of great significance.
|
Received: 12 May 2017
|
|
|
|
|
[1] |
Amis E S Jr,Butler P F,Applegate K E,et al.American College of Radiology white paper on radiation dose in medicine [J].J Am Coll Radiol,2007,4: 272-284.
|
[2] |
崔燕海,黄美萍,赵振军,等. 胸部X线摄片在健康体检中的合理应用--附8567例结果分析[J].放射学实践,2009,24(1):33-35.
|
[3] |
Bach P B, Mirkin J N, Oliver T K, et al. Benefits and harms of CT screening for lung cancer [J]. JAMA, 2012, 307(22): 2418-2429.
|
[4] |
Rampinelli C, De Marco P, Origgi D, et al. Exposure to low dose computed tomography for Lung cancer: secondary analysis of trial data and risk-benefit analysis [J]. BMJ, 2017, 356: 347.
|
[5] |
应向华,陈 洁.上海市医用CT配置和使用情况研究[J].中国卫生资源,2008,11(5): 210-211.
|
[6] |
张啸飞,冯 立,刘 兵. 低剂量MSCT筛查早期肺癌在临床中应用的可行性[J]. 职业与健康, 2009, 25(15): 1671-1672.
|
[7] |
Hendee W R,Becker G J,Borgstede J P,et al.Addressing overutilization in medical imaging[J].Radiology,2010,257:240-245.
|
[8] |
中华医学会放射学分会心胸学组. 低剂量螺旋CT肺癌筛查专家共识[J]. 中华放射学杂志, 2015,49(5):328-335.
|
[9] |
王国伟. 胸部低剂量螺旋CT在健康人群中筛查肺结节的应用价值分析[J].全科医学临床与教育,2014,12(6):633-635.
|
[1] |
. [J]. Med. J. Chin. Peop. Armed Poli. Forc., 2019, 30(9): 798-799. |
|
|
|
|