Effect of needle depth on respiratory amplitude during normal frequency jet ventilation |
ZHOU Hongling and XU Yuan |
Department of Anesthesiology, Beijing Tongren Hospital Affiliated to Capital Medical University. Beijing 100730, China |
|
|
Abstract Objective To observe the effect of needle depth on respiratory amplitude during normal frequency jet ventilation via the endotracheal tube.Methods A self-control study was performed on 18 patients undergoing surgery with tracheal intubation general anesthesia. Volume controlled ventilation (VCV) and jet ventilation were applied to patients in sequence. The depths of needles inserted into the endotracheal tube were 0cm (JV0), 4cm (JV4) and 8cm (JV8) respectively. The distances of Laser spot movement were measured in each ventilation mode and respiratory amplitudes were compared between different modes.Results The respiratory amplitudes during VCV, JV0, JV4 and JV8 were 0.28±0.09 cm, 0.51±0.16 cm, 0.43±0.16 cm and 0.28±0.11 cm respectively. The respiratory amplitude during JV4 was decreased when compared with JV0 (P<0.01) but was increased when compared with JV8 (P<0.01). The respiratory amplitude during VCV was comparable to JV8 and significantly decreased when compared with JV0 and JV4(P<0.01).Conclusions The needle depth has some effect on respiratory amplitudes during normal frequency jet ventilation. Our study suggests that the respiratory amplitude decreases with needle depth.
|
Received: 08 March 2019
|
|
|
|
|
[1] |
牛学功,刘鲲鹏,任宪凤,等.经硬式支气管镜高频喷射通气在气管与支气管肿瘤冷冻治疗中的临床应用[J].中华医学杂志,2018,98(24):1941-1944.
|
[2] |
Sivasambu B, Hakim JB, Barodka V, et al. Initiation of a high-frequency jet ventilation strategy for catheter ablation for atrial fibrillation: safety and outcomes data[J].JACC Clin Electrophysio,2018,4(12):1519-1525.
|
[3] |
Putz L,Mayne A, Dincq A S. Jet ventilation during rigid bronchoscopy in adults: a focused review[J].Biomed Res Int,2016,16:423.
|
[4] |
Baer G. Complications and technical aspects of jet ventilation for endolaryngeal procedures[J].Acta Anaesthesiol Scand,2000,44(10):1273-1274.
|
[5] |
李 娟,张 维,陈 宇,等.肺保护性通气对膝关节置换术中氧合功能及肺顺应性影响[J].武警医学,2017,28(7):668-671.
|
[6] |
Gottschalk A, Mirza N, Weinstein G S, et al. Capnography during jet ventilation for laryngoscopy[J].Anesth Analg,1997,85(1):155-159.
|
[7] |
谭 放,李绍清,陈莲华,等.不同频率喷射通气在支撑喉镜术中的通气效果及不良反应[J].上海医学,2010,33(10):915-918.
|
[8] |
尹凤先,张 杰,丁 彦,等.开放式喷射通气在犬全身麻醉下硬质气管镜介入治疗中的应用[J].中华结核和呼吸杂志,2011,34(11):821-826.
|
[9] |
Sütterlin R, Priori R, Larsson A, et al. Frequency dependence of lung volume changes during superimposed high-frequency jet ventilation and high-frequency jet ventilation[J].Br J Anaesth,2014,112(1):141-149.
|
[10] |
周娅梅.高频-常频程序喷射通气时不同喷射位置对通气效果的影响[D].温州:温州医科大学,2017:1-38.
|
|
|
|